FEM STUDY · v1.0
HRC, Monotonic Strength, Cyclic Yield Surface and 51CrV4/60Si2MnA Evidence (FEM-PRESET S13)
What data does a disc spring presetting FEM actually need for its material input? Is an HRC46 plus a pair of 1550/1600 MPa values usable? And why was the hardness-dimension parameter sweep paused? Evidence level H0 (historical reconstruction / method validation / parameter screening); no material calibration or production approval is claimed. Full member PDF: 19 pages.
Purpose
Solver / version
Material model
Boundary conditions
Applicability
Contact / friction
Mesh / convergence
A-L / manufacturer / FEM / experiment at equal displacement
| Displacement mm | A-L N | Manufacturer N | FEM N | Experiment N | FEM vs A-L |
|---|
Complete engineering data